BNRJD - 6075, DRY FILM LUBRICANT

  • MSDS: BNRJD
  • Manufacturer: CROWN
  • Product Name: 6075, DRY FILM LUBRICANT
  • National Stock Number: 9150-01-149-4890
Product Identification

Product ID:6075, DRY FILM LUBRICANT
MSDS Date:04/23/1986
FSC:9150
NIIN:01-149-4890
MSDS Number: BNRJD

Responsible Party
CROWN
12603 STATE LINE RD
HEBRON, IL 60034-0350
US

Emergency Phone: 815-648-2424

Info Phone: 815-648-2424

Preparer: ROBERT E. BAYTON

Cage: 06367

Contractor
CROWN INDUSTRIAL PRODUCTS CO
350 HEBRON, IL 60034 US

Telephone: 815-648-2424

Cage: 92381

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1.1.1 TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 51-70%

OSHA PEL 350 PPM;450 PPM STEL

ACGIH TLV: 350 PPM;450 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 1-10%

OSHA PEL 1000PPM;1250 STEL

ACGIH TLV: 1000PPM;1250 STEL


HYDROCARBON PROPELLANT; (LIQUIFIED PETROLEUM GAS,

CAS: 68476-86-8

Fraction By Weight: 31-50%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON/CHLOROFLUOROCARBON (CFC)
MATLS HAVE PRDCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDIC ATED EXCEPT FOR LIFE-SUSTAING USES
IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS/CFC'S . (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ACUTE: INHAL: SHORTNESS OF BRTH, DIZZ,
LIGHT HEADEDNESS. ANESTHETIC EFTS MAY OCCUR @ HIGH CONC. INGEST:
MAY CAUSE CHEM PNEUMONIA IF ASPIRATED INTO LUNGS. EYE:POSS
IRRITANT. SKIN CONT:SHORT CO NT - NO IRRIT. PRLNGD/RPTD CONT -
MINORTO MILD IRRIT. SKIN ABSORPTION: VERY LOW TOX. TARGET ORGANS
AFFECTED:(SUPP DATA)
Medical Cond Aggravated by Exposure:MAY CAUSE MYOCARDIAL IRRITABILITY.
AVOID EPINEPHRINE OR SIMILAR DRUGS IF AT ALL POSSIBLE.

First Aid

First Aid:CALL MD. EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES OR
UNTIL IRRITATION SUBSIDES. SKIN: REMOVE ALL CONTAMD CLOTHING. WASH
WITH SOAP AND WATER. INHAL: REMOVE FROM EXPOSURE IMMEDIATELY. IF
BREATHING IS IRREGULAR OR STOPPED BEGIN ARTIFICIAL RESPIRATION AND
ADMINISTER OXYGEN. INGEST: DRINK LARGE AMOUNTS OF WATER. DO NOT
INDUCE VOMITING.

Fire Fighting

Flash Point Method:TCC
Flash Point:SUPP DATA
Lower Limits:1.8%
Upper Limits:9.5%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE CHLORIDES, FLUORIDES & PHOSGENE . TREAT AS CYLINDERS OF
COMPRESSED GAS.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CLEAN UP WITH INERT MATERIALS. DISPOSE OF I/A/W ALL
LOCAL, STATE AND FEDERAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AEROSOL CNTNR:DO NOT STORE IN DIRECT
SUNLIGHT/NEAR OPEN FLAMES/@ TEMPS >120F. USE ONLY AS DIRECTED. NO
SMOKING IN AREA OF USE.
Other Precautions:DO NOT USE IN GEN VICINITY OF ARC WELDING, OPEN
FLAMES/HOT SURFS.HEAT &/UV RADIATION MAY CAUSE FORMATION OF
CHLORIDES, FLUORIDES/PHOSGENE .INTENTIONAL MISUSE BY DELIB CONC
VAPS & INHALING CONTEN TS CAN BE HARMFUL/FATAL.

Exposure Controls

Respiratory Protection:RESPIRATORY PROGRAM SHOULD BE I/A/W 29 CFR
1910.134. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENT: SEE 29
CFR 1910.132 & 133.
Work Hygienic Practices:WASH SKIN WITH SOAP AND WATER.
Supplemental Safety and Health
VP:50 PSIG W/O/V. FL PT:<20F (AEROSOL).HAZ DECOMP PROD:POINT, 372F,
BEFORE APPRECIABLE DECOMP BEGINS. SUBLIMATION AT LOWER MOLECULAR WT
FRACTIONS CAN OCCUR.ACTUAL SUBLIMATION RATE IS DEPENDENT UPON TE MP
AREA & AIR FLOW. CHLORIDES, FLUORIDES .HLTH HAZ:PRLNGD EXPOS >OSHA
PEL MAY RSLT IN KIDNEY & LIVER DAM.

Chemical Properties

Boiling Pt:B.P. Text:160F,71C
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:>1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:SLIGHT
Appearance and Odor:MILKY/ETHEREAL ODOR
Percent Volatiles by Volume:98

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTAMINATION WITH CAUSTIC SODA, CAUSTIC POTASH OR OXIDIZING
MATERIALS.
Stability Condition to Avoid:FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:THERMAL DECOMP MAY PRODUCE HYDROGEN
CHLORIDE ACIDS & SM AMTS OF PHOSGENE. IT CAN BE HEATED ABOVE ITS
MELTING (SUPP DATA)

Disposal

Waste Disposal Methods:AEROSOL CONTAINER: DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL OR PARTIALLY FILLED CONTAINERS ARE CONSIDERED
HAZARDOUS WASTE. DISPOSE OF I/A/W FEDE RAL, STATE AND LOCAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.